DER IEEE 1547 - IEEE 2030.5¶
Parameters¶
- poll_rate: Poll Rate for DERProgram (default: )
- pin: Client PIN (default: )
Operations¶
Get Operations¶
- Nameplate Information
- Configuration Information
- Monitoring Information
- Constant Power Factor
- Voltage-Reactive Power
- Active Power-Reactive Power
- Constant Reactive Power
- Voltage-Active Power
- Low Voltage Trip
- High Voltage Trip
- Low Frequency Trip
- High Frequency Trip
- Frequency Droop
- Enter Service
- Limit Maximum Active Power
Set Operations¶
- Configuration Information
- NP_P_MAX-AS: Active power rating at unity power factor (default: )
- NP_VA_MAX-AS: Apparent power maximum rating (default: )
- Constant Power Factor
- CONST_PF_MODE_ENABLE-AS: Constant Power Factor Mode Enable (default: )
- CONST_PF_EXCITATION-AS: Constant Power Factor Excitation (default: )
- CONST_PF_INJ-AS: Constant Power Factor (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- derp_write_path: DERProgram Path (default: )
- Voltage-Reactive Power
- QV_MODE_ENABLE-AS: Voltage-Reactive Power Mode Enable (default: )
- QV_VREF-AS: Vref (p.u.) (default: )
- QV_VREF_AUTO_MODE-AS: Autonomous Vref Adjustment Enable (default: )
- QV_VREF_OLRT-AS: Vref Adjustment Time Constant (s) (default: )
- QV_OLRT-AS: Open Loop Response Time (default: )
- QV_CURVE_V1-AS: Curve Point V1 (VRef p.u.) (default: )
- QV_CURVE_Q1-AS: Curve Point Q1 (VA Max p.u.) (default: )
- QV_CURVE_V2-AS: Curve Point V2 (VRef p.u.) (default: )
- QV_CURVE_Q2-AS: Curve Point Q2 (VA Max p.u.) (default: )
- QV_CURVE_V3-AS: Curve Point V3 (VRef p.u.) (default: )
- QV_CURVE_Q3-AS: Curve Point Q3 (VA Max p.u.) (default: )
- QV_CURVE_V4-AS: Curve Point V4 (VRef p.u.) (default: )
- QV_CURVE_Q4-AS: Curve Point Q4 (VA Max p.u.) (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Active Power-Reactive Power
- QP_MODE_ENABLE-AS: Active Power-Reactive Power Mode Enable (default: )
- QP_OLRT-AS: Open Loop Response Time (default: )
- QP_CURVE_P3-LOAD-AS: Curve Point P3 Load (W Max p.u.) (default: )
- QP_CURVE_Q3-LOAD-AS: Curve Point Q3 Load (VA Max p.u.) (default: )
- QP_CURVE_P2-LOAD-AS: Curve Point P2 Load (default: )
- QP_CURVE_Q2-LOAD-AS: Curve Point Q2 Load (default: )
- QP_CURVE_P1-LOAD-AS: Curve Point P1 Load (default: )
- QP_CURVE_Q1-LOAD-AS: Curve Point Q1 Load (default: )
- QP_CURVE_P1-GEN-AS: Curve Point P1 Gen (default: )
- QP_CURVE_Q1-GEN-AS: Curve Point Q1 Gen (default: )
- QP_CURVE_P2-GEN-AS: Curve Point P2 Gen (default: )
- QP_CURVE_Q2-GEN-AS: Curve Point Q2 Gen (default: )
- QP_CURVE_P3-GEN-AS: Curve Point P3 Gen (default: )
- QP_CURVE_Q3-GEN-AS: Curve Point Q3 Gen (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Constant Reactive Power
- CONST_Q_MODE_ENABLE-AS: Constant Reactive Power Mode Enable (default: )
- CONST_Q-AS: Constant Reactive Power Setting (VA Max p.u.) (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Voltage-Active Power
- PV_MODE_ENABLE-AS: Voltage-Active Power Mode Enable (default: )
- PV_OLRT-AS: Open Loop Response Time (default: )
- PV_CURVE_V1-AS: Curve Point V1 (VRef p.u.) (default: )
- PV_CURVE_P1-AS: Curve Point P1 (W Max p.u.) (default: )
- PV_CURVE_V2-AS: Curve Point V2 (default: )
- PV_CURVE_P2-AS: Curve Point P2 (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Low Voltage Trip
- V_TRIP_ENABLE-AS: Voltage Trip Enable (default: )
- UV1_TRIP_V-AS: UV1 - V (default: )
- UV1_TRIP_T-AS: UV1 - Time (default: )
- UV2_TRIP_V-AS: UV2 - V (default: )
- UV2_TRIP_T-AS: UV2 - Time (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- High Voltage Trip
- V_TRIP_ENABLE-AS: Voltage Trip Enable (default: )
- OV2_TRIP_V-AS: OV2 - V (default: )
- OV2_TRIP_T-AS: OV2 - Time (default: )
- OV1_TRIP_V-AS: OV1 - V (default: )
- OV1_TRIP_T-AS: OV1 - Time (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Low Frequency Trip
- FREQ_TRIP_ENABLE-AS: Freq Trip Enable (default: )
- UF1_TRIP_F-AS: UF1 - Freq (default: )
- UF1_TRIP_T-AS: UF1 - Time (default: )
- UF2_TRIP_F-AS: UF2 - Freq (default: )
- UF2_TRIP_T-AS: UF2 - Time (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- High Frequency Trip
- FREQ_TRIP_ENABLE-AS: Freq Trip Enable (default: )
- OF2_TRIP_F-AS: OF2 - Freq (default: )
- OF2_TRIP_T-AS: OF2 - Time (default: )
- OF1_TRIP_F-AS: OF1 - Freq (default: )
- OF1_TRIP_T-AS: OF1 - Time (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Frequency Droop
- PF_MODE_ENABLE-AS: Frequency Droop Mode Enable (default: )
- PF_OLRT-AS: Open Loop Response Time (default: )
- PF_DBOF-AS: dbOF (default: )
- PF_DBUF-AS: dbUF (default: )
- PF_KOF-AS: kOF (default: )
- PF_KUF-AS: kUF (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Enter Service
- ES_PERMIT_SERVICE-AS: Permit Service (default: )
- ES_V_LOW-AS: ES Voltage Low (VRef p.u) (default: )
- ES_V_HIGH-AS: ES Voltage High (default: )
- ES_F_LOW-AS: ES Frequency Low (Hz) (default: )
- ES_F_HIGH-AS: ES Frequency High (default: )
- ES_RANDOMIZED_DELAY-AS: ES Randomized Delay (default: )
- ES_DELAY-AS: ES Delay (default: )
- ES_RAMP_RATE-AS: ES Ramp Rate (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Limit Maximum Active Power
- AP_LIMIT_P_ENABLE-AS: Limit Active Power Mode Enable (default: )
- AP_MAX_P-AS: Maximum Active Power Setting (W Max p.u.) (default: )
- derc_start_time: DERControl Start Time (default: )
- derc_duration: DERControl Duration (default: )
- Constant Power Factor
- Voltage-Reactive Power
- Active Power-Reactive Power
- Constant Reactive Power
- Voltage-Active Power
- Low Voltage Trip
- High Voltage Trip
- Low Frequency Trip
- High Frequency Trip
- Frequency Droop
- Limit Maximum Active Power
- Constant Power Factor
- Voltage-Reactive Power
- Active Power-Reactive Power
- Constant Reactive Power
- Voltage-Active Power
- Low Voltage Trip
- High Voltage Trip
- Low Frequency Trip
- High Frequency Trip
- Frequency Droop
- Limit Maximum Active Power