DC Simulator - SPS

Parameters

  • comm: Communications Interface (default: VISA)
  • ipaddr: IP Address (default: 192.168.0.167)
  • ipport: IP Port (default: 4944)
  • visa_device: VISA Device String (default: GPIB1::19::INSTR)
  • visa_path: VISA Driver Path (default: visa32.dll)
  • curve_type: IV Curve Type (default: EN50530)
  • overvoltage: Overvoltage Protection Level (V) (default: 660.0)
  • pmp: EN50530 MPP Power (W) (default: 3000.0)
  • vmp: EN50530 MPP Voltage (V) (default: 460.0)
  • vmp2: MPP Voltage (V) (default: 50.0)
  • imp: MPP Current (A) (default: 2.3)
  • voc: Open Circuit Voltage (V) (default: 65.0)
  • isc: Short Circuit Current (I) (default: 2.5)
  • beta_v: Beta V (%/K) (default: -0.36)
  • beta_p: Beta P (%/K) (default: -0.5)
  • kfactor_voltage: K Factor V1 (V) (default: 60.457)
  • kfactor_irradiance: K Factor E1 (W/m^2) (default: 200)

Operations

Get Operations

  • Power
  • DC Output State
  • Device Info
  • Query
    • qstr: Query String (default: )

Set Operations

  • Power
    • power: Power (W) (default: )
  • DC Output State
    • state: DC Output State (default: )
  • Command
    • cstr: Command String (default: )