DC Simulator - Chroma Battery Sim¶
Parameters¶
- comm: Communications Interface (default: VISA)
- visa_device: VISA Device String (default: TCPIP::192.168.1.100::60000::SOCKET)
- visa_path: VISA Driver Path (default: )
- INIT: Initial Condition (default: )
- CAP: Battery Capacity (Ah) (default: 100)
- INIT_SOC: Initial SOC (%) (default: 50)
- SOC: SOC Step(%) (default: 100, 90, 80, 70, 60, 50, 40, 30, 20, 10, 0)
- OCV: OCV at SOC (V) (default: 41.1,40,39.1,38.3,37.6,36.9,36.6,36.3,35.9,35,33.8)
- DCR_D: Discharge DC internal resistance at SOC (Ohm) (default: 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.1)
- DCR_C: Charge DC internal resistance at SOC (Ohm) (default: 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.01, 0.1)
- ESR: DC internal resistance (default: 0.001)
- BVL: Low Voltage Alarm (V) (default: 10)
- VOLP: Low Voltage Protection (V) (default: 5)
- BVH: High Voltage Alarm (V) (default: 35)
- VOH: High Voltage Protection (V) (default: 40.1)
Operations¶
Get Operations¶
- Device Info
- Voltage
- Error
- Query
- qstr: Query String (default: )
Set Operations¶
- Power ON
- Power OFF
- **Instantiate the Device **
- Command
- cstr: Command String (default: )