DAQ - Yokogawa PX/WT/PZ Series¶
Parameters¶
- comm: Communications Interface (Recommend VXI-11 for Ethernet, VISA for USB/GPIB) (default: TCP)
- ipaddr: IP Address (default: 127.0.0.1)
- ipport: IP Port (default: 7772)
- visa_device: VISA Device String (default: GPIB0::13::INSTR)
- visa_path: VISA Driver Path (default: visa32.dll)
- sample_interval: Sample Interval (ms) (default: 1000)
- chan_1: Channel 1 (default: AC)
- chan_2: Channel 2 (default: AC)
- chan_3: Channel 3 (default: AC)
- chan_4: Channel 4 (default: DC)
- chan_1_label: Channel 1 Label (default: AC Phase A Channel)
- chan_2_label: Channel 2 Label (default: AC Phase B Channel)
- chan_3_label: Channel 3 Label (default: AC Phase C Channel)
- chan_4_label: Channel 4 Label (default: DC Channel)
- ftp_server: Start FTP Server (for screenshots and waveform data transfers)? (default: No)
- ftp_port: FTP Server Port (21 is required by Yokogawa) (default: 21)
- ftp_user: FTP User Name (Enter on Yokogawa Net Drive) (default: labtest_user)
- ftp_pass: FTP Password (Enter on Yokogawa Net Drive) (default: L8bT3st)
Operations¶
Get Operations¶
- Device Info
- Query
- qstr: Query String (default: )
- Current Power Data
- Output Current
- Load data log from csv
- filepath: CSV Path (default: )
- Harmonics
- orders: Harmonic orders to capture (default: 50)
- DC Component
- Waveform Via FTP
- comment: CSV Sheet Comment (default: )
- subsampling: Waveform Subsampling (default: 100)
Set Operations¶
- Command
- cstr: Command String (default: )
- DC Component
- Trigger
- pre_trig: Pre-Trigger Time (s) (default: 0.5)
- post_trig: Post-Trigger Time (s) (default: 2.5)
- sample_rate: Sample Rate (Hz) (default: 5000)
- trig_source: Trigger Source Channel (default: EXT)
- trigger_slope: Trigger Slope (default: RISE)
- Data
- Local FTP Server
- Waveform Results Processing
- file_path_override: Override Internal File Path (to use latest from FTP transfer: No) (default: No)
- sliding_window: RMS and Freq Sliding Window (s) (default: 0.1666)
- get_trip_time: Trip - Determine Trip Time (s) (default: No)
- trip_level: Trip - Pre-Disturbance Current Threshold (%) (default: 1.0)
- confirm_ride_through: RT - Verify Ride-Through Mandatory Operation (default: No)
- rt_level: RT - Pre-Disturbance Threshold (%) (default: 80.0)
- get_mc_cease_to_energize: MC - Determine Momentary Cessation Cease to Energize Time (default: No)
- mc_level: MC - Pre-Disturbance Current Threshold (%) (default: 1.0)
- get_mc_return_time: MC - Determine Momentary Cessation Return Time (default: No)
- mc_return_level: MC - Pre-Disturbance Return Threshold (%) (default: 80.0)
- Data
- Local FTP Server