AC Simulator - Keysight SL1200¶
Parameters¶
- phases: Phases (default: 3)
- v: Voltage (L-N Per Phase) (default: 277.2)
- v_max: Max Voltage (L-N Per Phase) (default: 300.0)
- i_max: Max Current (Total of All Phases) (default: 30.0)
- freq: Frequency (default: 60.0)
- comm: Communications Interface (default: TCP)
- ipaddr: SCPI Server IP Address (default: 127.0.0.1)
- ipport: SCPI Server IP Port (default: 5025)
- visa_device: VISA Device String (default: USB0::0x0A69::0x086C::662040000329::0::INSTR)
- visa_path: VISA Driver Path (default: )
- hardware_addr: SL1200 Hardware IP Address (default: 10.14.6.140)
- state: AC Output State (default: ON)
Operations¶
Get Operations¶
- Device Info
- AC Output State
- Voltage
- Frequency
- Voltage Harmonics
- Current Harmonics
- Voltage THD
- Current THD
- Query
- qstr: Query String (default: )
- Get AC Profile
- Get AC Profile Status
Set Operations¶
- AC Output State
- state: AC Output State (default: )
- Voltage
- v: Voltage - All phases (V) (default: )
- v1: Voltage - Phase A (V) (default: )
- v2: Voltage - Phase B (V) (default: )
- v3: Voltage - Phase C (V) (default: )
- Frequency
- hz: Frequency (Hz) (default: )
- hz_slew_rate: Frequency Slew Rate (Hz/sec) (default: )
- AC Profile
- prof_name: Profile Name (default: )
- Command
- cstr: Command String (default: )
- Start AC Profile