Customer Center

Software Downloads

Download the latest software, updates, documentation, and product data sheets. License requests and trial activations are available for all products.

Downloads

Products & Software

Product
login to download the latest
DownloadVersion DatasheetDocumentationLicense RequestTrial
DERSec LabTest Pro LabTest.zip 4.1.2 PDF HTML License Request Trial Request
DERSec LabTest Plus LabTest.zip 4.1.2 — HTML License Request Trial Request
DERSec DER Simulator After Licensing 4.1.2 PDF HTML License Request —
SunSpec Dashboard Dashboard.zip 4.1.2 — HTML Request —
DERSec Sentry After Licensing — PDF — License Request —
DERSync CSIP Aggregator (Cloud) After Licensing — PDF — License Request —
DERSync CSIP Gateway After Licensing — PDF — License Request —

Installation Note: Download the latest version of LabTest from the link above and install it. Launch LabTest, navigate to Application menu > Help > About, copy the Installation ID and submit it via the corresponding license request form. We will generate a license file and send it to you.

Release Notes

LabTest Changelog

  • [Pro/Plus/Dashboard] Results plotting: Q-V, P-V, Q-P, frequency-droop, and prioritization-Q-P plots no longer fail to open in the shipped Windows installer, the target / upper-bound / lower-bound curves extend horizontally to the plot edges instead of floating in mid-air, and the plot icon is hidden for results without a registered plotter (Monitoring, Nameplate, Configuration)
  • [Pro/Plus/dashboard]ITECH AC and DC source drivers: connect now sends *CLS + SYST:REMote + OUTPut OFF before changing function mode, so devices left in local mode or with output enabled on a prior session can be configured cleanly
  • [Pro/Plus/Dashboard] Secure SunSpec Modbus runnables: Windows OPENSSL_Applink crash on TLSF-001 / CRYP-001 fixed in the shipped installer -- the audit pcap keylog is now produced reliably; PICS workbook dropped its unused Control sheet and three unused control_* setup rows; dropped pyopenssl in favor of cryptography for the .slic chain check
  • [Pro/Plus/Dashboard] Secure SunSpec Modbus RTU-4 broadcast test: no longer false-positives against a device that correctly stays silent
  • [Pro/Plus/Dashboard] SunSpec device map JSON: new discovery_register field records the base register (0 / 40000 / 50000) where each model map was discovered
  • [Pro/Plus/Dashboard]Bump csip-server 1.1.28 -> 1.1.32, csip-aggregator 0.9.2 -> 0.11.3, dersim 1.6.7 -> 1.7.5
  • [Pro/Plus/Dashboard] Bump csip-server 1.1.26 -> 1.1.28, csip-aggregator 0.7.8 -> 0.9.2, dersim 1.5.10 -> 1.6.7, websockets 12.0 -> 13.1, pysunspec2 -> 1.3.6
  • [Pro/Plus/dashboard]Customer-facing quickstart accuracy fixes (Help -> About license-load flow, install location, product feature scope)
  • [Pro/Plus/Dashboard] Secure SunSpec Modbus runnables: SunSpec role selection for the test client certificate, TLS Version + Set Certificates toggles in the Open Device dialog, hardened role-extension parser, PICS styling improvements (Product Info tab, light-blue editable cells)
  • [Pro/Plus/Dashboard] SunSpec Conformance Profile v1.2: per-model values tests (MOD-3) generated for every model the device implements; MB-1 single/multi-register write is now model-agnostic and picks write values from each point's PICS-declared [min, max] range
  • [Pro/Plus/Dashboard] DefaultDERControl now registers its FSA entry in the FunctionSetAssignmentsList so the DUT can discover the control via the standard chain
  • [Pro/Plus/Dashboard]New Constant Active Power op: writes opModTargetW (Watts mode) or opModFixedW (Percentage mode) based on W_SET_MODE-AS, matching the SunSpec / DNP3 twin convention
  • [Pro/Plus/Dashboard] Set Active Power: fixed param-source bug that silently treated valid inputs as missing; Prated now auto-discovers from the device nameplate (DERCapability.rtgMaxW) when not set in script global params; opModTargetW is sent as the IEEE 2030.5 ActivePower struct; verification check no longer false-fails on a unit mismatch
  • [Pro/Plus/Dashboard] New Help -> Proxy Config dialog: trusts the OS certificate store and diagnoses corporate proxy / SSL-interception issues
  • [Pro/Plus/Dashboard] Corporate proxy support no longer interferes with local IEEE 2030.5 (CSIP) test connections
  • [Pro/Plus/dashboard] Bump csip-server 1.1.20 -> 1.1.26, csip-aggregator 0.7.2 -> 0.7.8, dersim 1.5.4 -> 1.5.10
  • [Pro/Plus/Dashboard] Bump csip-server 1.1.19 -> 1.1.20, csip-aggregator 0.7.0 -> 0.7.2, dersim 1.2.12 -> 1.5.4
  • [Pro/Plus/Dashboard] Fixed License files hierarchy
  • [Pro/Plus/dashboard] Bug fix: CSIP MUP testing
  • [Pro/Plus/Dashboard] Bump csip-server 1.1.13 -> 1.1.19, csip-aggregator 0.4.2 -> 0.7.0, dersim 1.2.10 -> 1.2.12
  • [Pro/Plus] Updated pysunspec2 to 1.3.4
  • [Pro/Plus/dashboard]Per-device nameplate / config / monitoring for the IEEE 2030.5 aggregator
  • [Pro/Plus] DERP poll rate driven by per-target parameters; "add DERP" wired into the 2030.5 target screen
  • [Pro/Plus] Standardized Modbus/TLS cert UI between client and DERSim configs
  • [Pro/Plus/Dashboard] Added units to every control field in scripting
  • [Pro/Plus/Dashboard] Bug fix: 2030.5 driver curve handling
  • [Dashboard] UI: dashboard footer no longer scrolls free of the bottom edge
  • [Pro/Plus/Dashboard] Bump csip-server 1.1.13, csip-aggregator 0.4.2, dersim 1.2.9
  • [Pro/Plus] Increased the window for response times in CSIP tests to +/- 5 seconds
  • [Pro/Plus/dashboard] Addition of TLS configuration for SunSpec Modbus driver in scripting
  • [Pro/Plus] CSIP aggregator tests check for subscription before prompting for client input
  • [Pro/Plus] Fixes to TerraSAS profile
  • [Dashboard] Bug fixes to the IEEE 2030.5 dsriver in scripting
  • [Pro/Plus] Bump csip-server 1.1.2, csip-aggregator 0.2.3, dersim 1.1.2
  • [Pro/Plus] Fix http_redirect_triggered access for unbundled csip-server
  • [Pro/Plus] Defer fdi lookup in BasicTest to avoid misleading startup error
  • Several CSIP Server and CSIP Client updates
  • [Pro/Plus] New websites for IEEE 2030.5 Server and DER Simulator
  • [Pro/Plus] Added XML schema validation to IEEE 2030.5 server
  • [Pro/Plus] DERSim fix: zero out DC power under AC faults
  • [Pro/Plus] License parsing fix with human-readable content
  • [Pro/Plus] Fixed bug in DER Simulator CSIP logger
  • [Pro/Plus] Added Privacy Policy to installation and UI
  • [Pro/Plus] Upgraded OpenSSL version for CSIP TLS connections
  • [Pro/Plus] Added xmlsx attributes to CSIP payloads
  • [Pro/Plus] Added IEEE 2030.5 CSIP-AUS functionality to server and client
  • [Pro/Plus] Added IEEE 2030.5 TariffProfiles to CSIP server and client
  • [Pro/Plus] Expanded DERSim CSIP UI including CSIP-AUS import/export and pricing
  • [Pro/Plus] Updated IEEE 2030.5 DER scripting functions for CSV uploads
  • [Pro/Plus] Added human-readable representation to the cached cloud license
  • [Pro/Plus] Bug fix for DERSim ↔ Server CSIP exchange
  • [Pro/Plus] Bug fix for CSIP management server in DER simulator
  • [Pro/Plus] Online licensing is available for all users
  • [Pro/Plus] Correction to BASIC-029 CSIP tests
  • [Pro/Plus] Better performance for CSIP server and client (reusing SSL threads)
  • [Pro/Plus] Created an accelerated CSIP AGG test suite
  • [Pro/Plus] Updated IEEE 2030.5 CSIP timing evaluation precision to use float values
  • [Pro/Plus] Update to IEEE 2030.5 target def to write default DERControl
  • [Pro/Plus] Bug fix: circular buffer for IEEE 2030.5 server website memory issue
  • [Pro/Plus] Cleaner IEEE 2030.5 CSIP COMM certification tests
  • [Pro/Plus] Fixed superseding event test responses
  • [Pro/Plus] Complete IEEE 2030.5 CSIP Client and CSIP Aggregator certification test suites
  • [Pro/Plus] DER Simulator CSIP Client interface on port 5000
  • [Pro] Fix DAQ start/stop threads for measurement data

Need Help?

Contact our team for enterprise licensing, custom deployments, or technical support.

Download Document


Request Trial License

Complete the form below to request a trial license for . We will generate a license file and email it to you.